306 apc alarm fanuc linkedin. It includes 60 alarm codes numbered 000 Fanuc 10tf, Axis Torque Alarm, mem Z axis Alarm, already changed Z drive and motor? Need Help!-414 SERVO ALARM: V AXIS DETECTED ERR , and 449 V AXIS: INV. You need to change the APZ to 0 first, before changing . View Profile Very Please help. the home position. Additional Suggestions & Alarm Clarification Absolute pulse coder, cable or scale faulty, Check to make sure parameters are set correctly and that someone did not try to turn the scale or encoder off or on while troubleshooting. If they go low, you will first get a LOW BAT alarm for days before they actually become so low that you lose your position data. when i opened to see the parameter 1815 APC was 1 and APZ was 0 on both axis, when i modified APC to 0 the alarm went off, and the FANUC: FANUC Zero Return Procedure If you have a Fadal machining center with the Fanuc Oi-M or 18i control, you will need to make sure you replace the axis backup batteries. 2. EKrol Aluminum. 304 apc alarm:n axis parity. By chatree_w in forum Fanuc Replies: 1 Last Post: 09-30-2011, 12:24 PM. fanuc alarm DS0300: APC Hello guys! I have a Mori Seiki NV4000 DCG center and i am totally stucked with this alarm message. This document lists alarm codes and messages for program errors on a CNC machine. Fanuc alarm: 350 - SPC ALARM: n AXIS PULSE CODER. lỗi trên bộ điều khiển fanuc 0i absolute pulse coder (apc) alarms. nth-axis (n=1-8) APC battery voltage has decreased to a low level so that the data cannot be held. Fanuc 16i 18i Alarms Codes You can Join at Our Group Facebook : CNC INDONESIA or Email :soekarno. The batteries in the control have died and I'm going to ALARM 306 TO 308 (ABSOLUTE PULSE CODER BATTERY IS LOW) Absolute pulse coder battery replacement Procedure. (axis battery zero). Troubleshooting Servo Amplifier Alarm U or L on a FANUC CNC. 201 for details. Sep 6, 2024. Having a problem running the machine. 5000 to 5999 P15: Page 61B–62755EN/01 1. Whe Fanuc Beta I/O Link Alarms. 300 APC Alarm. View Profile View Forum Posts Private Message View Gallery Uploads Member Join Date Jan 2013 Location england Posts 425 Downloads 0 Uploads 0. any help please Fanuc alarm: 306 - APC alarm: nth-axis battery voltage 0. Hello, I have a 9 axis machine that went down and the battery failed also. Release the E-stop press Fanuc 301 APC ALARM:n AXIS COMMUNICATION Fanuc APC (Absolute pulse coder) Alarm Description nth–axis (n=1 – 4) APC communication error. Oct 10, 2023 #2 Next time don't turn off the machine off with the APC light blinking. 417. Mar 22, 2012. Fanuc gives you the 300 alarm hello guys, I have a CNC Milling machine with 3 axes. Some were driven by a Fanuc power mate. Alarm Code: Description of Alarm/Error: 600: Interruption by illegal command is occurred: 601: Siemens Forum - Learn everything around the CNC production and can ask extensively about SINUMERIK at CNC4you. While inserting G28 and start cycle, nothing happends. I left the machine on, and changed out the batteries. TCM S Machine. Here you find more information about Siemens AG – 306 APC alarm: nth – axis battery FANUC FA card adapter ,FANUC Floppy cassette adapter, FSP–H 4 Not used 5 Portable ; Page 147B–63505EN/02 3. Siemens claim 6 weeks, not sure I’ve ever seen what Fanuc say. Nov 27, 2008 #1 Set parameter 1815. I've tried doing them in different orders (eg X first, then Z, etc. Press the System key. Page 21. If the machine is already in home position on start up then it will make this easier. By DanielBamek in forum Fanuc Replies: 4 Last Post: 06-23-2015, 07:34 PM. I've tried setting the APC bits to zero first, then back to 1. At the end of the pallet change an M64 DS0300 APC Alarm: Need Reference Return. the_gentlegiant. These Fanuc alarm code applies to Hello, we have this machine which sometimes when turned on will throw this alarm 300 APC - X axis need ZRN. You will not get an alarm for the X axis, as it is set to 1. Originally Posted by Justintro8487. FANUC Parts Specialists; E-MAIL 08:30 - 17:00 (APC) alarm Alarm Code: Type: Description of Alarms/ Faults: 300* 306* APC alarm: nth APC APZ NOTES . 306 APC ALARM:n AXIS BATTERY ZERO; 307 APC ALARM:n AXIS BATTERY DOWN 1; 308 APC ALARM:n AXIS APC alarm: nth axis battery low 2: nth axis axis APC battery voltage reached a level where the battery must be renewed( including when power is OFF) 3n9: Alarm in Fanuc PMC Model L/M. Fanuc Alarm 300 n AXIS NEED ZRN Fanuc APC (Absolute pulse coder) Alarm Description Manual reference position return is required for the nth–axis (n=1 – 4). Skip to content. Tezgah MDI moduna alınır. I have gotten bad ones before, you check the voltage prior to changing them. We have a Doosan Puma 2600LSY with a fanuc 0i control. Return to the repair page Errors list. Details & Solutions. Contact us. The battery only stores the Fired it up after sitting about a month and a half. 305 APC ALARM:n AXIS PULSE MISS; 306 APC ALARM:n AXIS Fanuc alarm: 309 - APC ALARM: n AXIS ZRN IMPOSSIBL. DS0300 (X) APC ALARM: RETURN REF DS0300 (Z) APC ALARM: RETURN REF EX1206 Máy CNC Fanuc bạn sử dụng sau 1 thời gian có thể hết Pin hoặc bạn tháo bộ Servo Amplifier hoặc Encoder ra sửa chữa thì sẽ mất gốc máy CNC và báo lỗi DS0300 A Re: Fanuc series oi-model MF alarm DS0300 The best way to fit exactly your reference points after a sudden bateryy loss,but APC message will blink yellow if the batery goes under 6V, is to touch th eworkpiece with your special dial gauge with what you set your G54,set the relative coordinates to 0 on all axes and move back to the origin points with the values that Good afternoon everyone, i need your help, i have a chevalier EM2040L with control FANUC SERIES OI-MF and today it showed an alarm EX1070, spindle oil pressure low error, do you know how to fix it? Oil level is full, pressure 15. I set it to 1, and I get the alarm to turn off the power, but it doesn't take the parameter change. Operational heads up: After a machining program runs and ends with M30, the machine moves without further operator input to change the pallet. 307 or 308 APC alarm, please replace the battery within a week following the instructions in 2. Fanuc Otd Alarm 310,320. 306 - APC alarm: nth-axis battery voltage 0. ds0300 (x)apc alarm: need ref returnds0300 (x)apc alarm: need ref returnds0306 (x)apc alarm: battery voltage 0ds0306 (z)apc alarm: battery voltage Having problem in my Bfw machine having fanuc controller of 300 APC alarm XYZ axis needs ZRN after relacing the batteries. 99% CERTAIN IT IS YOUR CABLE AS IT MOVES WITH THE MACHINE. Help Others Learn how to solve 300 APC alarm and replace battery on Fanuc CNC machines with this instructional video by @yclkorkmaz. 3. txt) or read online for free. CHANDRU Plastic. IF it is power mate driven, it would not show up on the fanuc diagnostics with the Our shop just acquired a used Fanuc Robodrill Alpha-T142A with the 16i-M control, along with a 5th axis Nikken 5AX-2MT-105-120 that was previously mated How to install the app on iOS. At this point, you need to go into Jog mode and jog the Z axis to where it physically is supposed to be for the reference position. It will not go into MDI or any other mode. RETURN DS0300 (Z) APC ALARM: NEED REF. 307 apc alarm:n axis Hello, we have this machine which sometimes when turned on will throw this alarm 300 APC - X axis need ZRN. A proper value ( 111 or -111) is not set in parameter no 2022. ALARM 306 TO 308 Good afternoon group, I have a problem with a Pinacho CNC ST180 lathe with FANUC Oi-TF control. 301 apc alarm:n axis communication. but after the alarm clear, u need sett zero post for each axis getting alarm. Home Fanuc Learn Examples Sinumerik Haas Troubleshooting Steps Alarm 301 to 305 Alarm 306 to 308 Serial Pulse Coder (SPC) Alarms (Alarm 350, 351) Troubleshooting Steps Alarm 350 Alarm 351 What is FANUC Servo Alarm 414? We have an alarm of 300 APC ALARM – X, Y, T & V-AXIS NEED ZRN- i already follow the steps on my manual, I already enable also the parameter write but still the SYSTEM KEY is not responding FANUC ALARMES COMPLETO. 3 Outputting PMC 1. Thread starter VSMI; Start date Mar 21, 2012; Replies 4 Views 20,372 V. reset both home positions, powered down, brought it back up and APC is still flashing. Refer to diagnosis display No. 01-26-2016, 05:36 AM #2. View Profile View Forum Posts Private Message View Gallery Uploads Registered Join Date Hello everyone. Knowledge Base. Ȧ All specifications and designs are subject to change without notice. after that sett the APC from 1 to 0 and then emergency stop+power off. '306 APC ALARM : A AXIS BATTERY ZERO' '306 APC ALARM : Hello friends ,in this video i told about battery replacement on cnc or and computer numeric fanuc control this video is pure practical video where i show e Drive battery charge Remove FANUC APC DRIVE BATTERY ALARM 300 APC Z AXIS NEEDS ZRN IS DISPLAYED) 1. After the christmas ho 595,384 members. Is there anyone out here in cnc land that would be willing to help me through this. Fanuc alarm: 351 - SPC ALARM: n AXIS COMMUNICATION. Joined Feb 26, 2007 Location INDIA. Set any Workshift values to ZERO. FANUC 0i MODEL D the axes use a pulse coder + linear scale to know it's position I want to remove the linear scale from the Y axis. Home. Reset X axis Zero position. View Tag Cloud. Fanuc Alarms In this video detail explanation of how to set reference of CNC machine . 3, * FANUC’s order number : A98L–0031–0006. underthetire. Please do not hesitate to contact us if you require further help or advice. Then power on again and change APC and APZ from 0 to 1 again. Joined Dec 29, 2006 Location Vermont. 07-22-2017, 12:38 PM #2. 305 apc vmc cnc apc alarm !!! ds0300 (x) apc alarm: need ref return !!! ds0306 (z)apc alarm: battery voltage 0 !! ds0306 (y)apc alarm: battery voltage 0 !! Also, 306 voltage of x,y, and z APC cell has been reduced briefly to level that cannot hold data. This is the model that has a full functional Fanuc control (not the "Alpha" code only version). finally i have concluded their is no Having issues with a Hardinge Conquest GT27-SP gang tool lathe ( bought new 2006 ) running Fanuc 21i-TB. Select MDI mode. Posting Permissions You When you get an alarm message No. 306. no actual alarms, just the blinking yellow apc I do sales and service of machine tools and I have a customer with a Ecoca CNC lathe with a Fanuc series 18 T control. JAMES_2000. A. first of all I start work on APC and have checked different sensors and limit switches of APC and checked their input output on ladder diagram. and 306 APC ALARM : X AXIS BATTERY ZERO which I'm guessing is a battery on a PCB somewhere. The power supply unit was defective. Control Model. gempar@gmail Fanuc 16i 18i Alarms Codes for CNC machinists. Fanuc APC 307 alarm question. 305 APC ALARM:n AXIS PULSE MISS; 306 APC ALARM:n AXIS Bảng mã lỗi máy CNC Fanuc – Máy CNC Hệ điều khiển Fanuc – Fanuc alarm codes list. This morning had the 300 APC alarm. View Profile View Forum Posts This alarm occurs when the n-th axis ( axis 1-4) is in one of the conditions below: ( Digital servo system alarm) The value set in Parameter no 20200 (motor form) is out of the specified limit. Power down and up again to clear battery voltage 0 alarm. 302 apc alarm:n axis over time. This FANUC Alarm code list covers: 0i Model A, 0i/0iMate Model B, 16/18 Model PB, 16/18 Model C, 16i/18i Model A, & many more FANUC fault codes. Have a Fanuc Robo drill T14iB with a kawatate c auto pallet changer. 6 VDC. Fanuc 21i Alarm Codes for CNC machinists. 16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i. 8. I have tried to home the x axis, but nothing wants to move on the machine. Reset tools. Fanuc alarm: 309 - APC ALARM: n AXIS ZRN IMPOSSIBL. Am I screwed or will it be ok once the new battery arrives and I install it? Similar Threads: Problem- 8. 308 APC alarm: nth–axis battery low 2 nth–axis (n=1 – 8) APC battery voltage has reached a level where the battery must be Re: APC 306 Battery zero alarm Going of the top of my head here, so you may want to double check me on this. Then the job ran fine for about 20 minutes after axis reset, then just stopped running during Hello everyone, I just bought Stama Fanuc MC010 with Fanuc OM Mate control. ≡ MENU. com/company/euroservo1https://twitter. I figure out how to remove the alarms by following the procedude of 1835 bit 4 parameters . 300 APC Alarm : Y Axis need zrn & 306 APC Alarm: Y axis battery zero on Fanuc 16i-LA. instagram. Ilgili ekseni APC ve 300 APC Alarm : Y Axis need zrn & 306 APC Alarm: Y axis battery zero on Fanuc 16i-LA. Servo module specification: A20B–2902–0070 or A20B–2902–0061 The machine is a millturn DOOSAN PUMA 2600LSY with fanuc i-series control We have the following alarms: PS0302 SETTING THE REFERENCE POSITION WITHOUT DOG IS NOT PERFORMED (after trying to zero the axes) DS0300 (Y) APC ALARM: NEED REF. First the message was " AXIS NEED ZRN ". Fanuc APC (Absolute pulse coder) Alarm Description An attempt was made to perform reference position return without rotating the motor through one or more turns. 306 APC ALARM:n AXIS BATTERY ZERO 307 APC ALARM:n AXIS BATTERY DOWN 1 308 APC ALARM:n AXIS BATTERY DOWN 2 309 APC ALARM:n AXIS ZRN IMPOSSIBLE 300 APC Alarm : Y Axis need zrn & 306 APC Alarm: Y axis battery zero on Fanuc 16i-LA. FANUC specification : A98L–0001–0902. How do i figure out the 0 positions? I've never ran this machine before so it is all new. Home Fanuc Learn Examples Sinumerik Haas Reference Alarms Programming About. Failure in data tra alarm 300 apc need reference in fanuc robocut 31iw model b . Also a good idea to reference all the axis' prior to changing the servo batteries. In addition, CNC also throws up Alarm 90 (REFERENCE RETURN INCOMPLETE) when we hit B+ button in Ref mode. Y 0 0 1 0 0 0 0 0 You will get the APZ alarm since it is at 0. . doosan ACE If an alarm is issued, replace the cable. A list of series 0iB, 0iC, 0iD Alarm and Fault codes. Press the Setting Softkey displayed on the screen and cursor to the PWE option. A setting to zero position for the absolute position detector (association with reference position and the counter value of the absolute position detector) is required. 08-01-2016, 01:46 PM #2. X axis Need ZRN. Here is the sequence of what was done. Alarm Code: Description of Alarm/Error: 600: Interruption by illegal command is occurred: 601: 306: APC alarm: nth-axis battery voltage 0: nth axis (n=1-8) APC battery voltage has decreased to a low I've never ran this machine before so it is all new. 6. Press "Setting" then "Setting" Soft Key (I think that is the soft When it boots back up, the APC alarm will still be there. Example of a trouble diagnosis guidance screen Kind of diagnosed Fanuc Series 16i/ 18i Troubleshooting Information/ Procedures/ Alarms. VSMI The threshold for that alarm is still above the point of losing memory. Cleared all the alarms MINUS 300 APC ZRN X AXIS and 300 APC ZRN Z AXIS - I am puzzled because when I bought the hi gents, i have an alarm on (vmc) fanuc Oi-mc, alarm number 300 it says x axis need zero, y axis need zero i had this alarm after i change the 2 batteries for (APC) after got low voltage ,and now when i switch the machine on i can't call the axis to home position, and got alarm number 300 my question is how can i call axis to home position and reset the alarm ? Khi hết pin máy thường báo các lỗi APC Alarm trên đây mình đã hướng dẫn cách sét gốc máy CNC hệ điều khiển Fanuc khi bị mất gốc nhưng các bạn nên thay pin định kỳ vì pin ngoài lưu gốc ra nhiều vị trí pin còn lưu thông Fitted with a "Harrison-GE Fanuc 21 i control. 308 apc alarm:n axis 306 APC alarm: nth – axis batter y Page 1GE Fanuc Automation Europe Computer Numerical Controls Series 21 i, 210 i - Model B Operator's Manual B-63614EN/01 TECHNOLOGY AND MORE ; Page 2Ȧ No part of this manual may be reproduced in any form. DS0300 APC Alarm: Need Reference Return. FANUC Parts Specialists; E-MAIL 08:30 - 17:00 306: APC ALARM:n AXIS BATTERY ZERO: 307: APC ALARM:n AXIS BATTERY DOWN 1: 308: APC ALARM:n AXIS BATTERY DOWN 2: 309: Problem-300 APC Alarm : Y Axis need zrn & 306 APC Alarm: Y axis battery zero on Fanuc 16i-LA; If this is your first visit, be sure to check out the FAQ by clicking the link above. _____INTP-002 ABORT Program manager internal errorCause: FANUC tape drill mate-MODEL T (with FANUC series O-MC (32-bits)) 1815 parameter for APC and APZ from 0 to 1. We have these two alarms on an OKK MCH-600 Mill. 140 bp/s alarm; absolute pulse coder (apc) alarms. i replaced the battery in mine. NH4000 on the machine, the damage to the battery I have the following alerts: EX0296 (224) Servo Alarm (magazine) EX1664 (224) Servo alarm (APC) EX1991 (224) Servo alarm (TLB) does anyone have the procedure, what to do? 302 apc alarm:n axis over time. Fanuc alarm: 308 - APC alarm: nth-axis battery low 2. By pacos in forum Fanuc Replies: 1 Last Post: 01-26-2016, 05:36 AM. 5. 6. SERVO Steps (Works for Fanuc 16,18,21, should work for yours, but do this at your own risk) 1. When replacing the memory backup batteries, keep the power to the machine (CNC) switched on, and hold the The alarm tells you that your x - axis encoder cable or the encoder is faulty. Push in the Emergency Stop button. Look into your manual for the procedure. Machine: Late 90's Mori SV-50 VMC Pallet Machine w/Fanuc 18MC. 0 " era : a mix of AI, plastics, human estrangement, When the batteries for the servo encoders are good the controller knows where zero was set even after power off. i want to know how I can treat this matter step by Vậy hôm nay cùng Heaco tìm hiểu cách khắc phục lỗi APC Alarm trên máy CNC Fanuc nhé! Lỗi APC Alarm. -The machine sends How to install the app on iOS. Not able to use machine with APC battery alarm. When i press Home Zero button it shows alarm "300, 306, 309" Alarms. 595,419 members. Changed batteries. Tags for this Thread. Fanuc 21iMB Fanuc 21i Alarms Program errors (P/S alarm) Program errors /Alarms on program and operation (P/S alar. FANUC Parts Specialists; E-MAIL 08:30 - 17:00 306: APC alarm: nth-axis battery voltage 0: If the alarm occurs immediately after power on when a cable or encoder was disconnected from the battery. RETURN The service guy at the dealer in my country say they have to send a technician for a full day to fix this issue. com/euroservomotor/https://www. I have managed to regain the reference positions on both x and z axis through parameter 1815. View Tag SERVO ALARM: n–TH AXIS – DISCONNECTION. Have questions about a FANUC CNC product? We're here to help. Replace the module corresponding to the axis indicated by the alarm, as shown in the figure below. 02-27-2013, 09:21 AM #2. Have CNC lathe, made by 'Metosa-Pinacho', model 'Mustang 200' control unit 'GE Fanuc 21i-T'. 1815 X 0 0 1 1 0 0 0 0 This is the way it should appear with no alarms. Reply. I don't know why. You may have to register before you can post: click the register link above to proceed. Fanuc part number A98L-0031-0011#L. as on machine screen alarm show possible fault occur in three different section. X axis Need ZRN; Need Help!-300/APC ALARM: AXIS NEED ZRN [4] Posted via Mobile Device It does move around using the Jog mode, and I know its Abosolute referencing, etc which it automatically knows its home position, once turned on but I'm currently getting alarm 300 - APC Alarm - Z RN (need to home). When I turn power on, go in MDI mode, I find no possibility of manual moving (except in JOG mode). Posting Permissions You may not post new threads; You may not Troubleshooting Servo Amplifier Alarm F on a FANUC CNC . Now APC 306 Battery zero alarm; Renishaw Tool Probe Battery Life; Newbie-Battery alarm; Fanuc 10T Backup battery life support; we are merely at the start of " Internet of Things / Industrial Revolution 4. Fanuc 16i/ 18i Maintenance Manual: B-63005E. 1. Fanuc 306 APC ALARM:n AXIS BATTERY ZERO Fanuc APC (Absolute pulse coder) Alarm Description nth–axis (n=1 – 4) APC battery voltage has decreased to a low level so that the Fanuc 305 APC ALARM: n AXIS PULSE MISS 1. Turned it on yesterday after it had set idle for some time and i get the following error: Alarm:" 300 APC Alarm: Z Axis need ZRN" Fanuc Series 0i alarms. Fanuc 21it Parameter question AlfaGTA; Hi, guys! I've been googling but i cannot find the answer to my question. If i set APZ to 1 by first set APC to 0 then APZ to 1 after that APC to 1, but after swithing power off and on APZ changes its state to Problem-300 APC Alarm : Y Axis need zrn & 306 APC Alarm: Y axis battery zero on Fanuc 16i-LA; Need Help!-Mazak QT 15 Alarm 14 Drive alarm z axis; Alarm 409-servo alarm- z axis torque alm; Posted via Mobile Device . Outline Machine alarms (External alarm message and Macro alarm) can be diagnosed on the trouble diagnosis guidance screen in addition to CNC alarms. Thread starter CHANDRU; Start date Nov 27, 2008; Replies 3 Views 10,571 C. it's giving the 300 APC ALARM : x axis need zrn z axis need zrn Similar Threads: 300 APC alarm; Problem-300 APC Alarm : Y Axis need zrn & 306 APC Alarm: Y axis battery zero on Fanuc 16i-LA; Need Help!-300 APC Alarm. axis, drive, gantry, labelled, zrn. Remedy: Check the teach pendant enable switch and other running programs to determine who hasmotion control. RETURN DS0300 (B) APC ALARM: NEED Fanuc 16i-M: 309 APC Alarm : B axis ZRN IMPOSSIBL (OKK MCH-600 Mill) 300 APC Alarm : B axis need ZRN; 309 APC Alarm : B axis ZRN IMPOSSIBL. APC alarm: nth–axis pulse error: 306: APC alarm: nth–axis battery voltage 0: 307: APC alarm: nth–axis battery low 1: 308: APC alarm: nth–axis battery low 2: 309: APC ALARM: n AXIS ZRN IMPOSSIBL: Serial pulse coder (SPC) alarms. V. 305 apc alarm:n axis pulse miss. 300 n axis need zrn. CNC Machine Control Manufacturer. Turned everything off and fired it back up. Anyone to These Fanuc alarm code applies to following Fanuc CNC controls Fanuc 16i/18i Model A Fanuc 16i/18i Model B F. when i opened to see the parameter 1815 APC was 1 and APZ was 0 on both axis, when i modified APC to 0 the alarm went off, and the Bu video, Fanuc kontrollü cnc makinasinda eğer eksen referans pilleri bitmiş ise pil değişimini, eksen referans noktalari kaybolmuş ise onu ayarlamayi anlatir. When you pull the battery you will get a 300 APC We have a Mori SH400 mill that starts up with an "APC motor is abnormal" alarm, EX0774 code. ( motor revolution direction). INPUT AND OUTPUT OF DATA 3. First replace battery's with machine on. 🌍https://euroservo. By diemaker in forum HURCO Replies: 2 Last Post: 08-05-2010, 04:00 PM. Change the "0" setting to "1". 5V We have a grinding machine with Fanuc 18-GC controller. E. X axis Need ZRN; Tags for this Thread. APC alarm. 307 apc alarm:n axis battery down 1. Position detection system fault in the n–th axis (axis 1–8) pulse coder (disconnection alarm). 2 or 2. RETURN DS0300 (B) APC ALARM: NEED REF. Alarm 306 states that the batteries are dead and need to be Fanuc 14T Robodrill I'm getting a 1014 APC alarm usually when pallet is going in or out. HARDWARE 111 WARNING Turn off the power to 300 APC Alarm : B axis need ZRN; 309 APC Alarm : B axis ZRN IMPOSSIBL. I've tried setting to 0 first (even though it's already at 0). VSMI Hot Rolled. servtech. My CNCzone Login If you have got Mantenimiento, cambio de baterías a maquina torno o centro de mecanizado CNC con control Fanuc Alarma APC efectuó cambio de pilas LR20/1. Battery or cable may be faulty. 300 n axis need zrn; 301 apc alarm:n axis communication; 302 apc alarm:n axis over time; 303 apc alarm:n axis framing; 304 apc alarm:n axis parity; 305 apc alarm:n axis pulse miss; FANUC Forum - The FANUC Newsroom on the IndustryArena includes a lot of important information on the FANUC FA Germany GmbH, a leading supplier of factory English PORTAL ALARM 300 APC Z AXIS NEEDS ZRN IS DISPLAYED) 1. ). The problem appears during searching reference points. any help solving this problem would be helpful, thank you. alarm, apc, fact, pallet , throws. 303 apc alarm:n axis framing. Power down and up again to clear battery voltage 0 alarm. (Fanuc 21 Model B) Fanuc Series 21-T CNC Control Fanuc 21 Alarm Codes 0 PLEASE TURN OFF POWER 1 TH PARITY ALARM 2 TV PA. parameter 1815 APC and APZ used to reference all the axis . Post troubleshooting recommendations for (Fanuc alarm: 306 - APC alarm: nth-axis battery voltage 0) error Anytime you disconnect a servo motor encoder cable you will get this alarm, this happens to be the turret. Can not find the details and solutions of this in my book. I have 310 apc alarm and don't know how to fix it. Meaning it lost reference for X axis, but n Y Axis need zrn & 306 APC Alarm: Y axis battery zero on Fanuc 16i-LA; Need Help!-300 APC Alarm. Type in1240 then press the No. As far I know, engine has absoluthe encoders, and on the DS0300 (Y) APC ALARM: NEED REF. Register Log After the christmas holiday I have an APC alarm flashing in yellow as well as a BAT alarm APC 306 Battery zero alarm; Problem-OSP 200L battery alarm; Newbie These FANUC Alarms are valid for following FANUC Controls: for the Fanuc series 16i, 18i, 21i controls. Press the Alarm fanuc ini valid untuk mengikuti kontrol fanuc cnc. Fanuc Powermate D Alarm 414 (LV5V Control Power Low Alarm) ALARM shuttle drawbar alarm haas; Need Help!-DAEWOO 8 Steady rest pressure alarm, Siemens Forum - Learn everything around the CNC production and can ask extensively about SINUMERIK at CNC4you. Problem-300 APC Alarm : Y Axis need zrn & 306 APC Alarm: Y axis battery zero on Fanuc 16i-LA; Total disconnection of axis; Alarm 420 on both X and Z axis on fanuc 6T; Need Help!-Alarm 414 z Axis FAnuc 18M; Posted via Mobile Device . 14 This alarm is generated when absolute pulse coder battery becomes low. Fanuc Series 16i/ 18i/ 16i-MA/ 18i-MA/ 160i-MA/ 180i-MA Troubleshooting Information/ Procedures/ Alarm codes Replacement procedure for Backlight on LCD display Fanuc 16i/ 18i/ 21i SRAM backup Báo động xung mã hóa Fanuc 21i: 301 APC ALARM: Lỗi giao tiếp APC(n = 1 - 4) 302 APC ALARM: quá giờ APC ALC APARM 303: Lỗi khung APC 304 APC ALARM: Lỗi chẵn lẻ APC 305 APC ALARM: Báo động lỗi xung APC Have CNC lathe, made by 'Metosa-Pinacho', model 'Mustang 200' control unit 'GE Fanuc 21i-T'. FANUC Parts Specialists; E-MAIL 08:30 - 17:00 +44 (0) 1793 615356; FANUC Parts Specialists; 306: 3: The motor was overheated (OHAL) 308: 6: Fanuc 309 APC ALARM:n AXIS ZRN IMPOSSIBLE. Press the "Input" key (This should display P/S 100 alarm). i ve replaced the original batteries with set of 8 dura cell in each slot,will I had the same Alarm on my mori seiki lathe (300 APC) I did the PRM setting as you said, but even after enabling parameter setting and Fanuc Alarm List - Fanuc Alarm Codes for CNC machinists. Fanuc Series 18-T APC alarm fix. Hi, I have the same or very similar problem with Fanuc Oi Mate -TC, battery alarm along with APC - 300 on bith Z and X axis, battery i replaced and that alarm went off however i'm still stuck with the other one. following action have taken for resolving. sansgp Plastic. tr📞+90 530 414 21 24https://www. We have it back up however I need to re-zero x/z on both upper and lower. S. Iam using Romi Bridgeport Powerpath 15 lathe machine which using fanuc 21i-t controller. Fanuc. Once the battery has been changed then the axis must be referenced. B–63505EN/02 2. Fanuc gives you the 300 alarm to let you know that the zero positions have been lost. it's giving the 300 APC ALARM : x axis need zrn z axis need zrn 301 apc alarm:n axis communication. Replace the battery. pdf - Free download as PDF File (. Search soft key and make a note of the Z axis value. Meaning it lost reference for X axis, but normally when batteries which hold axes position run out, this alarm would show on all three axes, not just one When it does that, you normally reference axes and it's all good, replace batteries and your good to go 580,356 active members* 11,347 visitors online* Register for free Login Have a nice little Harrison 330s Plus CNC lathe that is fitted with a Fanuc 21i control. Here you find more information about Siemens AG – Fanuc alarm: 306 - APC alarm: nth-axis battery voltage 0. This is the information Fanuc Program errors (P/S alarm) and alarms when incorrect functions are attempted within the program cycle. 7. Good morning everyone I have a problem with an APC alarm not resetting on a Doosan 2600m operating off a fanuc i series. In addition, Fanuc 18i : 309 APC Alarm : B axis ZRN IMPOSSIBL (OKK MCH-600 Mill) Thread starter sansgp; Start date Nov 10, 2016; Replies 3 Views 10,232 S. The problem is we are far away from them and they will bill a huge amount just on travel expenses. 305 APC ALARM: n AXIS PULSE MISS; 306 APC ALARM: n AXIS BATTERY ZERO; 307 APC ALARM: n AXIS BATTERY DOWN 1; 308 APC ALARM: n AXIS BATTERY DOWN 2; 309 APC ALARM: n AXIS ZRN IMPOSSIBLE; Failure in data transmission Possible causes include a faulty APC, cable, or servo interface module. The batteries should be 3. Ofset sayfasına girilir ve PWE değeri 1 yapılır. CAUTION. Nội dung bài viết. The latest problem is once it calls for the pallet to chan Problem-300 APC Alarm : Y Axis need zrn & 306 APC Alarm: Y axis battery zero on Fanuc 16i-LA; Problem-Machine Alarm 1014; 02-21-2022, 11:31 PM #2. 1:ATC 2:MAGZINE SIDE:3 APC SIDE. 9. Return to the origin has been attempted without first rotating the motor one or more times. You will get this when the battery goes dead as well. Rotate the motor through one or more turns, turn off the power then on again, then perform reference position return. Machine Alarm 1014. 595,384 members. alarm code 300 APC – A axis need ZRN. Replace the batteries for absolute pulse coder when NC power is ON. Fanuc 10tf, Axis Torque Alarm, mem Z axis Alarm, already changed Z drive and motor? Need Help!-Mazak QT 15 Alarm 14 Drive alarm z axis; Need Help!-300 APC Alarm. (GE Fanuc) Was attempting to to clear an "X" and Z servo alarm Log in Register. I have a lathe with Fanuc control Oi Mate-TC and as it was in disuse I changed the batteries of the encoders and I want to know where a. 2. View Profile View Forum Posts Registered Join Date Feb 2006 Posts 1792. – Có một va chạm cơ khí. If you have any advice, I'd appreciate it. 0i Model A; 0i/0iMate Model B; 16/18 Model PB; Model C 16/18; 16i/18i Model A; Model B 16i/18i; 16iL Model A; 20i; 306 APC ALARM:n AXIS BATTERY ZERO; 307 APC ALARM:n AXIS BATTERY DOWN 1; 308 APC ALARM:n AXIS BATTERY DOWN 2; 309 APC ALARM:n AXIS ZRN IMPOSSIBLE; 300 APC Alarm : Y Axis need zrn & 306 APC Alarm: Y axis battery zero on Fanuc 16i-LA. By cm747 in forum Fanuc Replies: 2 วิธีแก้ Alarm 300 หรือ 306 Fanuc สงสัย หรือ ติดต่อเพิ่มเติมได้ครับ 300 APC Alarm : Y Axis need zrn & 306 APC Alarm: Y axis battery zero on Fanuc 16i-LA Hi guys, Someone that help me whit this alarm's. Hurco VM2 swing arm alignment -no power on. Alarm in Fanuc PMC Model L/M. Contact a FANUC expert today. Push in the Emergency Change the "0" setting to "1". My problem occurs when I try to adjust the zero of the turret to the work piece in parameter 1850 (grid shift). Please can anybody help me with this ? What it means? Is it something about lost memory? :idea: If it is parameters memory Fanuc alarm: 306 - APC alarm: nth-axis battery voltage 0. What's new. 307 APC alarm: nth–axis battery low 1 nth–axis (n=1 – 8) axis APC battery voltage reaches a level where the battery must be renewed. Service Fanuc. Fanuc alarm: 360 - n AXIS : ABNORMAL CHECKSUM (INT) Page 1GE Fanuc Automation Computer Numerical Control Products Series 16 / 18 / 160 / 180 Overheat alarm P6: Servo alarm P7: System alarm P8: APC alarm P9: Spindle alarm P10: P/S alarm No. com. Additional Suggestions & Alarm Clarification. IPM ALARM; Need Help!-Alarm 414 Servo Alarm : Y axis detect error; Problem-300 APC Alarm : Y Axis need zrn & 306 APC Alarm: Y axis battery zero on Fanuc 16i-LA Fanuc Repair. sinha_nsit. Series 16 option 2 board: JS1A–2 to JS6A–2 Series 18 option 2 board: JS1A–2 to JS4A–2 3 Replace the servo module. Alarm Description. I found a battery inside the fanuc 21i-t controller and i replaced that one. First replace the batteries if they drain quickly you must determine which pulse coder or cable is shorted and drawing the battery down. Non of the axis are moving. Been battling for days. But i can't find any battery like that on my Servo drive or on the machine. Replace or repair the Fanuc 306 APC ALARM:n AXIS BATTERY ZERO Fanuc APC (Absolute pulse coder) Alarm Description nth–axis (n=1 – 4) APC battery voltage has decreased to a low le (3) Absolute pulse coder (APC) alarm438 Fanuc O-TC Battery Alarm will not reset? The battery needs to be changed. alarm, axis, cnc, inv, ipm. Thread starter Duck Waddell; Start date Oct 12, 2020; Replies 3 For us the APC alarm generally just means battery voltage low. I input the information and then the APC Hi, I have the same or very similar problem with Fanuc Oi Mate -TC, battery alarm along with APC - 300 on bith Z and X axis, battery i replaced and that alarm went off however i'm still stuck with the other one. 309 - APC ALARM: n AXIS ZRN IMPOSSIBL. Fanuc alarm: 307 - APC alarm: nth-axis battery low 1. Joined Mar 2, 2023. When the batteries go dead then the machine no longer knows where machine zero is. CHETAN DESAI says: February 14, 2022 at 4:06 pm. Press the Offset/Setting Key. By pacos in forum Fanuc 01-26-2016, 05:36 AM. คลิปวีดรโอนี้ วิธีแก้ Alarm 310 320 Fanuc OT OMถ้าหากสงสัยอะไร หรือสอบถาม Fanuc 21 alarm codes complete list. 5 (APC) to “1” for both X & Z FANUC Forum - The FANUC Newsroom on the IndustryArena includes a lot of important information on the FANUC FA Germany GmbH, a leading supplier of factory English PORTAL hie all, in marshall roboturn xl machine there is 4 cnc's having oi td series with one robo and in one cnc machine displaying alarm( DS0309(X1) APC ALARM: REF. 4. Nguyên nhân máy bị mất gốc tọa độ máy – Tháo động cơ hoặc drive. When i check i can found that its because APC battery down. Phil. If you let me have your email address then I can send you a detailed procedure. Replacing the batteries with power OFF causes the APC alarm. Parametre sayfasına girilir 1815 yazılıp No src tuşuna basılır. Thanks in advance Home > Fanuc > Alarm Codes > INTP Alarm CodesFanuc INTP Alarm CodesINTP-001 PAUSE Cannot lock the motion grpCause: Motion control for the specified group cannot be locked. ALARM 306 TO 308 (ABSOLUTE PULSE CODER BATTERY IS LOW) I've checked a couple other posts about this Fanuc alarm, but I wasn't able to come up with a plan to correct it. (i don't care of the accuracy) I tried to remove it but these alarms appeared: DS0300 (Y)APC ALARM: NEED REF RETURN DS0307 (Y)APC ALARM: BATTERY LOW 1 i cannot change parameter 1815 #4 z to 1 it says zrn impossible i did x and shut down and now i cant do z it is on a robodrill with a fanuc 16i controller it shows up as a alarm 309 Similar Threads: Need Help!-MAZAK VTC-16 Alarms- 280 (tool clamp impossible) 284 (spindle orient impossible) Need Help!-Quite impossible to work with ok i have resolve this issue. Joined Feb Fanuc 16 alarm and series 18 error codes for various 16M, 18M, 16T, 18T controls covering various model A, B, C faults and common alarms. X axis Need ZRN; Need Help!-300/APC ALARM: AXIS NEED ZRN [4] Need Help!-300 300 APC Alarm : Y Axis need zrn & 306 APC Alarm: Y axis battery zero on Fanuc 16i-LA. 306 apc alarm:n axis battery zero. Register Log in. Re: 300 APC Yup! Fired up the Takisawa Gang Style lathe and got a multitude of 300 APC alarms. pdf), Text File (. alarms Fanuc alarm: 306 - APC alarm: nth-axis battery voltage 0. Shoestring Machining. com/euroserv If one of the servo batteries was the problem it should have generated a 306 battery low _ axis alarm. Got the zero battery alarm. Common Alarm Codes and Errors for the Beta Servo Amplifier covering the A06B-6093-H15x/H17x series. RETURN IMPOSSIBLE) at time of refrencing, if i try to set APZ to 1. I turn off the machine and when I turn on it again the alarm APC 306 disappear ,Now the alarm APC 300 is still appear I Know that is request for reference posithin return to ZRN Z-axis. Search 306 APC Alarm: X Axis Battery Zero 306 APC Alarm: Z Axis Battery Zero About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Problem-300 APC Alarm : Y Axis need zrn & 306 APC Alarm: Y axis battery zero on Fanuc 16i-LA; 03-23-2023, 08:29 AM #2. nwnkzwlecckujbjdfmihyvnhuiotgdfecvoroytzrqxdwis