Jk bms rs485 protocol

Also try the pylontech, Goodwe and fss canbus from the JK as they also worked with my SMA. The last letter C in the model number means that has a CAN port. 2-RS485-V1. 0 1 4 B+ Jun 5, 2020 · I will present my DIY CAN BMS emulator project , I work from some time to make this interface for integration of DIY battery with different brands of invertors with supported CAN or RS485 communication. Be careful of the Vbat as that can be 50+V or more. JKBMS 2019-10-24T02:07:50+00:00 JK-B1A24S CAN BUS Protocol. RS485 RS485/CAN Entry cable Same port Single voltage range 1~5 V Voltage acquisition accuracy ±5 mV Overcharge protection voltage 1. Use Seplos LV or LI LV protocol is same as pylon with few data changed. Sends over CAN bus to inverter: Battery Voltage. I attached the Sigineer manual as an JK BMS held a professional BMS engineer team have more than 10 years experience in the electronics/battery BMS field, strength to design and produce the most innovative and high quality active battery balancer and active balancer BMS for li-ion,lifepo4, NMC, Ni-MH,Ni-Cd, Lead-acid batteries, red-flow batteries, VRLA and AGM batteries,etc. HEXR0 X 8 bBattery Warning Messa. JK BMS held a professional BMS May 9, 2024 · 1. 0 1 3 Interface Board JK-CN-Link-V1. The ESPHome project mentioned another way to connect directly to the JK but sounds a bit risky. 2v @3. The Dongle plugs into the BMS but the dongle ends in 3 bare wires at the other end. Hello! I have a Phocos Any Grid Inverter and I have recently bought 16 EVE 280ah batteries. The equalizer is suitable for 2 to 24 strings of battery packs with voltage acquisition and equalization. Name Model Qty 1 BMS Board JK-PB1A16S-20P 1 2 Display Screen LCD-3. Cascading installation of several equalizers is probably only possible when 24 batteries are fully occupied. JK-PB2A16S20P Support · syssi esphome-jk-bms · Discussion #447 I have some of the older JK BMS that i've been using with this project (thanks a million). Download. 2v/cell nominal. On my 8K inverter, the BMS communication protocol is Type # 12 and I have a RJ45 cable connected to the RS485 on the Inverter and the other end to the RJ485 port on the Battery BMS. Oct 23, 2021 · Panama. Dec 20, 2020. You can do the same with Arduino, if you have a free serial/UART port on it. Unlike RS232, RS485 has a 10 mbit/s data transfer rate. We have connection via RS485 but it is not stable - it will drop communication and then the inverter will change the group / battery pack Note Pylontech uses 15s/48v Goodwe uses 16s/51. Aug 22, 2021 · there is a BMS port (ref 14 on page 4), then on page 16 they say "Three lithium battery BMS communication protocol options" If the remote control is like an on/off switch, the BMS can control it directly from one of its outputs If one of the 3 communication protocol options is CAN SAE J1939 there is high chance theBMS can communicate with it. . The current plan is support JK-BMS and JBD/Overkill BMS(in Alpha testing) interface to inverters, including multi BMS support(WIP). 3 - From RS485 Protocols i tested only Fronius Gen24, The Pylon RS485 LV and Semplos RS485 LV are write from documentation for PC App -> Battery communication JK BMS RS485 Communicate Protocol Manual. From that it looks like the battery just sends status updates to the growatt. JK-BD6A20S6P. This video should clear things up on how to connect the new JK Inverter BMS via RS485 to your PC to do firmware updates and also change settings. When the battery is full then export to grid 80-120W. Overview Updates (2) History. misterbubbacat said: Nope, the Deye supports both CANBus and RS485 ModBus protocol for BMS communication. 7K resistor for 5V to 3. JK-BD6A24S6P. : Product Model JK-PB2A16S-20P Version V14. 3. When reading all the data, 0 x 79 is followed by a byte length data, and then every three byt. C++ 100. This BMS is compatible with Feb 7, 2020 · The ESP32 communicates with the JK-BMS using the RS485 port (GPS) which is in fact not RS485, it is 3. Definition: Dry Contact 1-PIN1 to PIN2: NC, closed during fault or protection; Dry Contact 2-PIN3 to PIN4: NC, closed for low voltage alarm. 0 1 4 B+ Specification Confirmation Form Customer Name: Customer No. smart bms lifepo4. Familymandan; May 29, 2024; BMS (Battery Managment Systems) 2. A RasPi, 2 RS485 port and some Python code. Product Overviews: Battery Active Equalizer (JK-B2A24S RS485) is a balanced solution for large-capacity series lithium battery packs Management system. 4. · 1. Protocol converter from the JK-BMS status frame to Pylontech CAN frames. th Oct 29, 2021 · 2 - Pylontech LV - if u use this protocol some inverter limit max charge voltage under 54V for 15S LFP battery. Heating Function. Other battery profiles that utilise the pylonton/goodwe protocol with differnt cell counts may also work, eg Alpha Ess Smile, BYD Battery-Box LV Flex Lite Select the correct battery profile in the inverter to match your battery pack! JK-B2A24S RS485. temperature rs485. Other battery profiles that utilise the pylonton/goodwe protocol with differnt cell counts may also work, eg Alpha Ess Smile, BYD Battery-Box LV Flex Lite Select the correct battery profile in the inverter to match your battery pack! Jul 10, 2023 · For 48S u can try to read RS485 or Serial from Daly So u will need : Esp32 DevKit 1 1 X CAN : SN65HVD230 - for inverter 1 RS485: Max485 - to read data from daly / or use direcy UART 2 RJ45 Breakout 1 DC-DC: XL7015 - take power form daly 12V pin For 66s 1 x JKBMS + 2 jk balancer if u want to read the current also JK-PB2A16S20P BMS Specification 9. Here is the CAN protocol for the JK BMS. If you have multiple on the one CAN bus, they would all be sending similar CAN data, making it difficult to determine which BMS it came from. 2v grade A cells. There's some pylon tech emulatorcode on github, but it's for CAN not RS485. Dry Contact. What kind of battery to select in the Solis app menu so that Solis inverter communicates with the JK bms? I have RS485 connector for the growatt and plan to use a raspberry pi to emulate a supported battery. etypeR0x79Single battery voltage3 *nHEXThe first byte is the b. Nov 27, 2021 · Ok, here is where the vendor communication issue comes from: RS-485 and CAN are provided by external modules. 1 The BMS sets the data identification code. The ESP32 then sends the required CAN bus data to the inverter via a TJA1050 CAN bus transceiver. This is a Python module based of the compilation from my Kaitai Struct. co. Then, I connected these 2 pins to RS485 TTL converter. Its marked A/H and B/L in the board and its the RS485 connector. As announced in the beginning I made a sigrok BMS protocol decoder, which can be used in PulseView or DSView and a wide range of logic analyzer hardware. 0 Modbus 1 10 EPEVER EPEVER_BMS_RS485_Modbus_Protocol V1. 05 Battery type Note Pylontech uses 15s/48v Goodwe uses 16s/51. Jul 10, 2023 · The situation is the same with shows as with connection to serial2 (rs485). It is one of the most widely used communication protocols, especially in noisy industrial areas. The equalizer uses a supercapacitor as a medium to achieve active energy transfer equalization. : Product Model JK-PB1A16S-20P Version V14. JKBMS 2019-10-24T02 JK-B2A24S CAN BUS Protocol. Sep 14, 2023 · Comunication between ESP32 and Inverter thru RS485 (Pylontech protocol) Uksa007 / esphome-jk-bms-can Public. esphome-jk-bms-can. Ethernet cable connected to rs485 port and Growatt "BMS" port. I already communicate with my Sigineer Inverter and (5) Solar Charge Controllers this way. I created this to compare BMS readings for a detailed evaluation of BMS reliability and accuracy. 3 2018/08/21. So vendors are correct: if you need RS-485 for example, you need the modules so that the TTL signal becomes an RS-485 signal. This smart bms with CANBUS/RS232/485 module is compatible with the lifepo&lithium NCM battery pack. He has developed a solution that uses an ESP32 device to communicate with a JK-BMS via RS485 or BLE, and then send the battery data to an inverter via CAN bus. I already have a 4. Simple enough, but I don't know if the RS485 protocol is the same (probably not). I presume these are RS485- GND, A+, B+. On the SolarAssistant configuration page, select the protocol below. Steve_S. Feb 12, 2021 · Menu Item 32 set to RS485 and Menu Item 33 set to PYL=PYLONTECH. Dec 28, 2023. To connect battery BMS, need to set the battery type as “LI” in Program 05. #532. . Replies 26 Views 1K. This is the brand new JK-BMS with a lot of new and interesting features. May 19, 2024. I tried using 16 batteries. Mar 11, 2022 · The JKBMS RS485 pinout should be GND, TX, RX, Vbat. RS485 is most useful in large-scale energy storage systems where batteries are distributed over a wide area. local Nov 29, 2019 · Hi Sergea . I scrolled down in the MPP doc and did not find any unusual item on it. Direct connection of wires. If you do not have RS485 marked in the BMS, it won't work (plus they wont have the RS485 connector even if they are labels in the board). 35 V adjustable Over discharge esphome-jk-bms-can. RS485 to TTL module (you don't need this if your ESP32 is near the JK-BMS) Various safety devices: Fuse and ZJ Beny125A DC circuit breaker Display Screen. The main functions are: CANBUS communication,RS485 communication,passive balance,individual cell over voltage protection,Over(under)voltage Note Pylontech uses 15s/48v Goodwe uses 16s/51. ABOUT US. It supports a flexible multi-drop system where a bus can accommodate multiple devices. Two devices can communicate with each other over a long distance (up to 1200m) using RS485 communication. #1. Specification Confirmation Form Customer Name: Customer No. mpp-solar/usage. A single JK-B2A24S CAN BUS equalizer is suitable for battery packs with 2-24 strings of batteries in series. When inverters use energiju from the battery then work well (export to grid or export to grid between -10 and +10W). I have the RS 485 communication protocol from Voltronic - ( Ellis /Lory/ Jenny 2020/03/25 ) and for Pylontech Ver 3. It is equipped with advanced features such as voltage collection, active large current balancing, overcharge, overcurrent, overtemperature protection, Coulombmeter, Bluetooth connectivity, GPS remote, and many more. JK inverter About JK BMS. Also more working interpretation for it (with RasPi) on Github. You can choose RS485 communication protocol which is from L01 to L50, and you can also choose CAN communication protocol which is from L51 to L99. JK BMS 200Amp 24 cells (16 in use) on a voltronic IGRID TT 10kW inverter. 2. This has all the hardware needed to communicate with BMS and Inverter over CAN bus. #4. The JK Deye canbus worked with my SMA SI5048, as you have sorted out the 4 and 5 pins it should work. Serial should work fine as well. CAN is the most common method that inverters use, there is only a couple that seem to only have RS485. The next two photos are the battery options and settings in the phone app. 2023-07-20. Other battery profiles that utilise the pylonton/goodwe protocol with differnt cell counts may also work, eg Alpha Ess Smile, BYD Battery-Box LV Flex Lite Select the correct battery profile in the inverter to match your battery pack! Jul 10, 2023 · The JK BMS are only connected to 16 batteries each. I am wanting to use the RS485 port to communicate with my PLC (Programmable Logic Controller). Feb 13, 2022 · Hi Herman, i have the same setup. Jul 1, 2021 · It seems Sol-Ark supports Pylontech, which is one of the more common protocols. ( i use Google- Übersetzer) The next problem is the communication with the JK-BMS and the Growatt inverter. 5. Notifications Nov 29, 2019 · Apr 4, 2022. May 9, 2024. Didn't work. Hello, I have a 51,2V 16s DYI battery with Lifepo4 EVE 3. 1 Main Specifications Apr 10, 2020 · And we already have JK Heltec RS485 BMS protocol documentation. 3 Modbus 4 11 PYLONTECH RS485-protocol-pylon-low-voltage-V3. 6A to 5A series, and support max continuous discharge up to 350A. 35 V adjustable Discharge time of charging overcurrent 2~120S adjustable Over discharge protection voltage 1. Interface Definitions Dry Contact Interface Definition Pin No. JK BMS held a professional BMS engineer team have more than 10 years experience in the electronics/battery BMS field, strength to design and produce the most inavative and high quality active battery balancer and active balancer BMS for li-ion,lifepo4, NMC, Ni-MH,Ni-Cd, Lead acid batteries, red-flow batteries, VRLA and AGM batteries,etc. JK-BD6A20S10P. Jun 4, 2021 · They read the JK info from the RS485 port. 5kw G4 inverter. It is suppled with either when ordered, but not both protocols. Z. Jul 10, 2023 · 2 - Invertor protocol u need - i am using Pylontech protocol, i do not mind other protocols as long as its one that is listed in the Solis inverter options 3 - status of ur project - I would say 95 % completed , - not sure if the GPIO will change if i find your solution which would mean reflashing of the ESP32 chips Jul 10, 2023 · I will present my DIY CAN BMS emulator project , I work from some time to make this interface for integration of DIY battery with different brands of invertors with supported CAN or RS485 communication. Location. Daly BMS connections settings to PYLON - RS485. โมดูลจอแสดงผล lcd. It should send the CAN messages after power-up according to the protocol, but you will need to make sure you have your CAN receiver set to 250 kbps and have the 120 ohm termination resistor on, otherwise it may stop sending messages. NOTE: If you would like me to add a BMS or inverter module just let me know! I would appreciate support to test the Step 2 - Configure SolarAssistant to connect to a JK BMS. g. Jan 26, 2023 · I am using 20S003 (old 300A JBD BMS) with UART&RS485 marked in the BMS. Maybe there are newer documents available . X. upnorthandpersonal. Dec 25, 2019 · I was hoping there was someplace in North America that had it stocked already. They call it RS485 because the RS485 adapter plugs in there (the 4 pin socket), but the signal at that port is UART/TTL, and can therefor be connected to a UART/TTL to USB converter. Also u can connect without adaptor direct to Serial port 1 : jkbms - > jk rs485 - > rs485 port of interface 2 : jkbms - > Serial port of interface CAN PORT of interface - > Invertor With one interface take data from 2 jkbms and send to can on invertor. May 29, 2024. This is where the project by Uksa007 comes in. Working voltage: 20~100V. I have successfully tested the following USB-RS485 converters and adapters with Louis’ driver and also the new JK Inverter BMS: Waveshare Industrial USB To RS485 Converter with FT232RL Chip The most expensive adapter in the round but this was confirmed by several people in forums to be working. Using bluetooth on the Home Assistant host system, it does not need any additional hardware (no USB/Serial/RS485). There is little point as the RS485 provides Feb 25, 2021 · The video help smart bms user to understand Daly Smart BMS UART、RS485 Connection set up Note Pylontech uses 15s/48v Goodwe uses 16s/51. 4US $ 26% OFF|1a/2a Active Balance Battery Protection Board Smart Bms 7s ~ 24s 100a 150a 300a Can Rs485 Gps App Lifepo4 Li-ion Lto Jk 16s 20s - Battery Accessories & Charger Accessories - AliExpress Jul 10, 2023 · Ur JkBMS have the GPS port where u connect jk rs485 adaptor. 5. Jul 10, 2023 · 2 - Pylontech LV - if u use this protocol some inverter limit max charge voltage under 54V for 15S LFP battery. Oct 19, 2023 · 1. I have the 5kw 48v 230v version: The SMA CAN protocol is used by many eg Pylontech, LG and Goodwe. The above active balancing BMS with active balancing current cover from 0. since the inter comms is the same as before, there is no reason why it would not work in a mix configuration . It is in the repo under decoder/bms/ to install it for a single user move it into ~/. It would open up this BMS to be much more useful for home energy storage applications, if it could communicate with the inverter. 4. ttery number, and the second is the voltage value mV. These describe the RS-485 protocol for Heltec/JK balancers, also applicable to their BMS. 0 Date Accessory List No. 1 *wm:Starting Web Portal Small in size, easy to use, and packed with features, the BMS may be found in many battery PACKs for different products including solar power stations, walkers, shared cars, high-power storage, base station backup power, and tiny sightseeing automobiles. change voltage) exactly/when the BMS wants (although the inverter can be programmed on its own, this is less than ideal). ESPHome component to monitor a Jikong Battery Management System (JK-BMS) via RS485 or BLE. This add-on reads the BMS and sends sensor data through MQTT to Home Assistant. ESPHome component to monitor and control a Jikong Battery Management System (JK-BMS) via UART-TTL or BLE - syssi/esphome-jk-bms Please find attached a different RS485 protocol document, sent to me by IC GOGOGO Store for the BMS I bought from them. RS485 is a half-duplex transmission method that allows the data Specification Confirmation Form Customer Name: Customer No. Have the RS-485 modules for the BMS, but it doesn't even have an address. I understand the pictures in Growatt manual led me to connect it initially wrong, to pins 7-8, which does not work. Tulcea, Romania. 2V 280Ah cells witk JK BP2A16S20P BMS and CANbus and I would like to purchase a Solis S6-EH1P6K-L-PRO inverter. Dec 11, 2020 · 25. Data Monitor JK-BMS RS485 Protocol. Interface use an esp32 with one or tow CAN ports and RS485 support, can handle multiple JK as inputs for data, and also cand handle LV or HV. I have this also mentioned on my Github, and have Python code there to talk to the BMS: Feb 7, 2020 · Sigrok Protocol Decoder. Be aware that tere are two models of the JK 485 adapters. : Customer Part No. Pinout for RJ45 port is Pin1 = RS485 B and Pin2 = RS485 A - note it is standard rj45 pinout. 3 and Goodwe V1. The new JK BMS with the CAN/RS485 port can be either RS485 or CAN. I have ordered and currently waiting for delivery the JK BMS B1A20S15P and I would like someone to help me on communication via RS485 protocol. Other battery profiles that utilise the pylonton/goodwe protocol with differnt cell counts may also work, eg Alpha Ess Smile, BYD Battery-Box LV Flex Lite Select the correct battery profile in the inverter to match your battery pack! Oct 30, 2023 · Im new to the DIY battery side of things and have built a 320ah battery using 16x3. to read from the bms. Delphinus, lincomatic and Steve_S. BMS can support up to max 16 units in parallel operation. 3-20180821 Telecom 2 12 MERITSUN Master-Slave board RS-485 Communication Protocol Telecom 2 13 FOXESS Introduction The BD6A20S12P Active Balancer BMS is a cutting-edge lithium battery smart BMS designed for large capacity series lithium battery packs. JK BMS held a professional BMS engineer team have more than 10 years experience in the electronics/battery BMS field, strength to design and produce the most innovative and high quality active battery balancer and active balancer BMS for li-ion,lifepo4, NMC, Ni-MH,Ni-Cd, Lead-acid batteries, red-flow batteries, VRLA and AGM I have designed and build a Hardware interface baord pictured below on the left. I show in all details how to connect to the Jun 4, 2021 · You will need a RS485 to UART adapter, in addition to the JK adapter. Note Pylontech uses 15s/48v Goodwe uses 16s/51. Select one or more USB cables and click connect: Plug the RS485 USB cable into the SolarAssistant monitoring device. Contribute to ismarintan98/JK_BMS development by creating an account on GitHub. A wide range of BMS and inverters already supported (see below). Also the protocol is different it seems The connection speed on the BMS card is max 19k2, but the JK BMS communicates with 115k2, so BMS is much faster. And, of course, it also has an active balancer onboard, so no need to install one or even worry about cell deviation. 2 inch color LCD. cpp files are modified copies of the code from Syssi. Main technical parameters: JK-BD6A20S10P. √ Yes No. cpp files are modified copies of ESP home code. 3V TTL so it can be directly connected to the ESP32. Supports sending of total capayity for SMA and Luxpower inverters. These modules convert the existing TTL/UART signal to these protocols. Dec 20, 2020 · RS-485 Heltec (JK) BMS. Jun 24, 2024. The interface is CAN/RS485. Python package to communicate to MPP Solar PIP-4048MS inverters (and similar) - mpp-solar/usage. You will need a RS485 to UART adapter, in addition to the JK adapter. You would have to write your own CAN decoder. Sep 16, 2023 · Therefore, you need a device that can translate the data from your JK-BMS to your inverter’s CAN bus protocol. forked from syssi/esphome-jk-bms. The Inverter to BMS cable probably uses pins 7&8 on the inverters BMS RJ45 jack which needs to go to the correct pins on the BMS end. #10. Definition 1, 8 RS485-B1 2, 7 RS485-A1 3, 6 GND No is the short answer but it may be possible to use a raspberry pi to read from the jk BMS and then emulate a battery protocol to the inverter. Definition: Enable heating when cell temperature is below -20°C during charging, stop heating at -10°C. May 26, 2022 · JK-BMS 150A model JK-B2A24S15P; JK RS485 module (you don't need this if your ESP32 is near the JK-BMS) ESP32 model esp32doit-devkit-v1; TJA1050 CAN bus to TTL module 4. Name Model Qty 1 BMS Board JK-PB2A16S-15P 1 2 Display Screen LCD-3. Hello, I am looking for the JK BMS RS485 Communicate Protocol Manual. 35 V adjustable Overcharge release voltage 1. Nov 29, 2020 · When energy from panels is higher which uses load and battery, and battery is under current limitation, export to grid is 50-60W. This document should help: If you are using or plan to use a JK BMS I have CAN comms working see: ESPHome component to monitor a Jikong Battery Management System (JK-BMS) via RS485 or BLE, CAN bus Goodwe/Pylon - Uksa007/esphome-jk-bms-can. sergea said: I have the RS485 BMS version, it as a dedicate RS485 port where the CANBUS was before, and and a pair of RS485 for inter battery communication, documentation is available in resource section of the forum. They are all similar hence why they work but the Deye may prefer one over another. 3 - From RS485 Protocols i tested only Fronius Gen24, The Pylon RS485 LV and Semplos RS485 LV are write from documentation for PC App -> Battery communication esphome-jk-bms-can. It is a plug and play device, just add power (5v USB) Hand built on a PCB and soldered to the ESP32, bulletproof design for production use. 0%. JK-B1A24S15P. This time, it comes as an inverter BMS, so it can communicate with almost any inverter on the market via CAN or RS485. I have added a JK-B2A24S20P BMS with RS485 converter which after some research seemed to be the best option as it has a 2a active balancer and has both CAN and RS485 inputs. I have also just received their RS485 Dongle. 0 1 4 B+ mppt charger 60 แอมป์. 168. Below bluetooth active balancing BMS also support RS485/CANBus for optional are available for sell: JK-BD6A17S6P. smart bms 16s 48v JK BMS RS485 CAN โมดูลและอะแดปเตอร์จอแสดงผล LCD สวิทช์กระตุ้น จอแสดงผล | Lazada. Maybe the BMS firmware version is different from yours? In the last photo, the parameters of Dec 26, 2023 · RS485 is a serial communication protocol. JK-B2A24S20P. Other battery profiles that utilise the pylonton/goodwe protocol with differnt cell counts may also work, eg Alpha Ess Smile, BYD Battery-Box LV Flex Lite Select the correct battery profile in the inverter to match your battery pack! The UART-TTL (labeled as RS485) socket of the BMS can be attached to any UART pins of the ESP. Languages. Display of BMS information, Cell voltages, statistics and alarms on a locally attached serial 2004 LCD. (Configurable temperatures) May 26, 2022 · JK-BMS 150A model JK-B2A24S15P; JK RS485 module (you don't need this if your ESP32 is near the JK-BMS) ESP32 model esp32doit-devkit-v1; TJA1050 CAN bus to TTL module 4. Via RS485/Modbus, Master/Slave. You can understand the JK protocol from that project. md at master · jblance/mpp-solar. A hardware UART should be preferred because of the high baudrate (115200 baud). RS485 to TTL module (you don't need this if your ESP32 is near the JK-BMS) Various safety devices: Fuse and ZJ Beny125A DC circuit breaker Jun 2, 2021 · Mounted file system Reading config file Opened config file, size = 142 Serial Protocol 1 BT Protocol 0 Can Protocol 1 Device ID OK *wm:AutoConnect *wm:Connecting to SAVED AP: STF *wm:connectTimeout not set, ESP waitForConnectResult *wm:AutoConnect: FAILED *wm:StartAP with SSID: JkBMS *wm:AP IP address: 192. Name Model Qty 1 BMS Board JK-PB2A16S-20P 1 2 Display Screen LCD-3. Jul 27, 2021 · And we already have JK Heltec RS485 BMS protocol documentation. BMS supports 2A active balance. 6 Modbus 1 9 Sunnew Sunnew xxSxxP ESS Protocol V1. Other battery profiles that utilise the pylonton/goodwe protocol with differnt cell counts may also work, eg Alpha Ess Smile, BYD Battery-Box LV Flex Lite Select the correct battery profile in the inverter to match your battery pack! Mar 24, 2022 · Apr 17, 2023. components/uart/ * and /core/ * headers and . I know that in SRNE inverter settings. Just skip the CAN/ESPhome stuff, and look for the parsing of the JK data. Optional linear reducing maximum current above 80% SOC (values can be adapted to your needs). Once you click "connect" on the configuration page, you should see each BMS show up as a battery pack 7 Sacredsun 485 Modbus Protocol V1. 3v level shift. If you get the RS485 cable from JKBMS it fix that for you, but if you use your own converter raw you might need to get a 5V source on the BMS (just check on of the other pins) There are 2 tipes of convertion cables. UK. Other battery profiles that utilise the pylonton/goodwe protocol with differnt cell counts may also work, eg Alpha Ess Smile, BYD Battery-Box LV Flex Lite Select the correct battery profile in the inverter to match your battery pack! Aug 2, 2020 · 7. May 22, 2024 · When JK introduced the PB BMS series they changed RS485 protocols and the Uart port acts differently too. Jul 10, 2023 · JKBMS < -> UART to RS485(ik adaptor) <=====> RS485 to UART (max485) <- >interface As u see u have JK RS485 adaptor on the bms side , and on interface side u have an other Max485 to convert back to UART , that why u can connect directly without any adaptor JKBMS UART<=====> UART interface and for Deye use CAN May 16, 2024 · 836. But in the JK bms settings the Pylon protocol is grey out and cant be selected. : Product Model JK-PB2A16S-15P Version V14. 3 Modbus 1 8 Ritar Modbus-BMS-protocol V1. For a battery pack with 24 strings of batteries connected in series, the wiring method is shown in Figure 3. 74kw PV going to a X1 Solax 7. Jun 28, 2021 · New Member. The equalizer works for 2A The equalized Oct 23, 2021 · JK BMS ans Kreuz(alte verwurmt DaCHLATTE) genagelt :-) i glaub der Wurm is noch drinProjekt Batterie erstellt und mit dem JK verheiratetEs kann losgehn 3. The official CAN bus support from JK I believe is only enabled if you order the CAN model, despite the port being present. bundyblu commented · Oct 18 2023 at 9:52 PM. Definition Note 1 COM1 S1 and COM1 conduct for alarm state 2 S1 3 COM2 S2 and COM2 conduct for low battery 4 S2 CAN and RS485-1 Interface Definition RS485 - 8P8C Upright RJ45 Socket Pin No. After set “LI” in Program 05, it will switch to Program 36 to choose communication protocol. Thanks for the reply . May 14, 2024 · The RS485 protocol is widely applied in BMS systems for long-distance communication. 2~4. New JK-BMS, 8S-16S, 24V 48V, 100A-200A. With this can write a Heltec to Lib BMS communication conversation. So, to get to business: components/jk_bms/* and components/jk_modbus/* headers and . Now my idea is to use a laptop instead of Venux GX for these reasons: Venux GX would not be connected to the inverter, therefore it will not have chances to react (e. I connect to series 2 without an rs485 converter, as well as to series 1. But when the battery pack. Any BMS or inverter can be supported in a very short time by just mapping the manufacturers protocol specification in an own implementation of the BMS or Inverter. This fork supports CAN bus communication with inverters supporting the CANBUS Protocol compatible with Pylontech V1. Dec 19, 2023 · The JK-BMS CAN port on OG models uses it own proprietary CAN protocol that is not compatible with any inverters. When the voltage is lower than 40V, the equalizer needs to provide external DC 40V~100V power supply. yn hv mc ce eu ed dh of vv lp